"$ElBoundary" 修訂間的差異

出自 DDCC TCAD TOOL Manual
前往: 導覽搜尋
(已建立頁面,內容為 " related commands $schottkyba, $ifelectrode , $ElBoundary, $extraElBoundary, $extraElBoundaries")
 
行 1: 行 1:
  +
Format:
  +
  +
$ElBoundary
  +
boundary number
  +
surface(in GMSH) contact_number schottky_adjust_value
   
   
  +
For example:
  +
  +
$ElBoundary
  +
2
  +
10 4 0.00
  +
80 3 0.00
  +
  +
  +
  +
  +
note that: 3 drain 4 sorce 2 gate 21 no current gate
  +
  +
  +
  +
For example2:
  +
  +
$ElBoundary
  +
2
  +
10 2 0.00
  +
80 2 +/-0.50
  +
  +
if there were two gate contact with default schottky value is 3.5eV
  +
then, the 10_surface would be 3.5 eV Schottky barrier.
  +
but, the surface of "80" would be 3.0eV or 4.0eV (depends on the sign)
   
   

於 2018年8月3日 (五) 22:04 的修訂

Format:

 $ElBoundary   
boundary number
surface(in GMSH) contact_number schottky_adjust_value


For example:

$ElBoundary                           
2
10  4  0.00     
80  3  0.00    



note that: 3 drain 4 sorce 2 gate 21 no current gate


For example2:

$ElBoundary                           
2
10  2  0.00     
80  2  +/-0.50    

if there were two gate contact with default schottky value is 3.5eV then, the 10_surface would be 3.5 eV Schottky barrier. but, the surface of "80" would be 3.0eV or 4.0eV (depends on the sign)


related commands