| 第14行: | 第14行: | ||
<br>'''<big><big>The $gatewithworkfunc setting in GUI interface is here</big></big>''' <br> | <br>'''<big><big>The $gatewithworkfunc setting in GUI interface is here</big></big>''' <br> | ||
Press | Press '''Contact Setting''', check the box, and fill in the field!<br> | ||
[[檔案:2D_gatewithworkfunc_fig1.jpg|1200px]]<br> | [[檔案:2D_gatewithworkfunc_fig1.jpg|1200px]]<br> | ||
於 2024年9月22日 (日) 15:26 的最新修訂
This function is used when the gate contact is adjacent with two or more materials that has different affinities. To activate this, use can just fill in the work function of the metal contact and this function should be used with the $affinity. For example:
$gatewithworkfunc 5.1
$affinity 4.05 1.25 2.35
Then the work function of the gate contact is 5.1 eV. If the contact material is 4.05eV, then the Schottky barrier is 1.05eV.
The $gatewithworkfunc setting in GUI interface is here
Press Contact Setting, check the box, and fill in the field!
![]()