*Information about each component being control.
*Information about each component being control.
*Is store as '''newPP %''' '''dev_type1''', '''dev_ID1''', '''port1''', '''dev_type2''', '''dev_ID2''', '''port2''' in the fortran code.


format
'''format'''
  emitting element     emitting element ID    output port    receiveing element    receiveing element ID    input port     
  dev_type_t   dev_ID_t    dev_type_r    dev_ID_r    method    ctrl_period    start_time    operating_time    data_record_sw    time2slot_sw


example
dev_type_t:controller<br>
dev_ID_t:controller ID<br>
dev_type_r:the component being controlled<br>
dev_ID_r:the ID of component being controlled<br>
method:The method of controlling component. The meaning of the numbers varies depending on the component.(laser:0.normal, 1.decoy)<br>
ctrl_period:If necessary, the control period can be set to a fixed value. Otherwise set to -1 and take control on call.<br>
start_time:System start time<br>
operating_time:System operating time<br>
data_record_sw:Decide whether to store event data<br>
time2slot_sw:<br>
 
'''example'''
  @INFO
  @INFO
  'CTRLER', 1, 'LASER',    1, 0, -1, 0,  -1, .FALSE., .FALSE.
  'CTRLER', 1, 'LASER',    1, 0, -1, 0,  -1, .FALSE., .FALSE.
第12行: 第22行:
  'CTRLER', 1, 'SPD', 2, 0, -1,  0,  -1, .TRUE. , .TRUE.
  'CTRLER', 1, 'SPD', 2, 0, -1,  0,  -1, .TRUE. , .TRUE.


Note: While the [[@PORTPAIR_NUM]] is 5, @PORTPAIR has 5 entries.
Note: While the [[@CTRL INFO NUM]] is 4, @PORTPAIR has 4 entries.

於 2025年1月30日 (四) 13:08 的最新修訂

  • Information about each component being control.

format

dev_type_t   dev_ID_t    dev_type_r    dev_ID_r    method    ctrl_period    start_time    operating_time    data_record_sw    time2slot_sw

dev_type_t:controller
dev_ID_t:controller ID
dev_type_r:the component being controlled
dev_ID_r:the ID of component being controlled
method:The method of controlling component. The meaning of the numbers varies depending on the component.(laser:0.normal, 1.decoy)
ctrl_period:If necessary, the control period can be set to a fixed value. Otherwise set to -1 and take control on call.
start_time:System start time
operating_time:System operating time
data_record_sw:Decide whether to store event data
time2slot_sw:

example

@INFO
'CTRLER', 1, 'LASER',    1,	0,	-1,	0,  -1, .FALSE., .FALSE.
'CTRLER', 1, 'PM'   ,    1,	2,	-1,	0,  -1, .TRUE. , .TRUE.
'CTRLER', 1, 'SPD',	 1,	0,	-1,     0,  -1, .TRUE. , .TRUE.
'CTRLER', 1, 'SPD',	 2,	0,	-1,  	0,  -1, .TRUE. , .TRUE.

Note: While the @CTRL INFO NUM is 4, @PORTPAIR has 4 entries.