$areacontact is the command to make the setting of contact area more flexible. The command is used to assign the metal/semiconductor surface contact within assigned area range. The format is
$areacontact N_contacts Contact_type Shape f1 f2 f3 f4 ... Contact_type Shape f1 f2 f3 f4 ... ... ... ... repeat N_contacts
- type : 21 is Gate, 3 is source, 4 is drain. 9 is for fix thermal boundary, 91 is thermal diffusive boundary
shape now only support 1, which is rectangular shape (f1,f2,f3,f4) = (x_min,x_max, y_max,y_min)
For example:
$areacontact 2 21 1 2.0 20.0 4.2 4.0 4 1 22.0 30.0 3.2 3.0
The $areacontact setting in GUI interface is here
1. After setting up the general structure, press Set Area Contact.
![]()
2. Press Add new epitaxial ranges and set up the contact type to Gate with its ranges.
![]()
3. As you can see, there is a new contact as needed!
![]()