「$ifTversusJ」:修訂間差異
跳至導覽
跳至搜尋
已建立頁面,內容為 "$ifTversusJ is the command to estimate the temperature in the channel loss. The command is $ifTversusJ 1 thermal_resistance_P1 <math> T = T_{ref} + P1 * pow..." |
無編輯摘要 |
||
| (未顯示由 2 位使用者於中間所作的 3 次修訂) | |||
| 第2行: | 第2行: | ||
$ifTversusJ | $ifTversusJ | ||
type thermal_resistance_P1 | |||
Currently type is 1. | |||
<math> T = T_{ref} + P1 * power_loss </math> | <math> T = T_{ref} + P1 * power_loss </math> | ||
P1 is the thermal resistance <math> P1 : K/(W/cm^{2}) </math> | |||
Power loss would be the joul-heat-loss, nonradiative recombination loss, Auger recombination loss | Power loss would be the joul-heat-loss, nonradiative recombination loss, Auger recombination loss | ||
$ifTversusJ | |||
1 0.01 | |||
<big>'''The $ifTversusJ setting for 1D-DDCC in GUI interface '''</big> <br> | |||
The parameters are modified in '''Step 3'''.<br> | |||
[[檔案:1d_$ifTversusJ_fig1.jpg|1300px]]<br> | |||
於 2024年11月22日 (五) 10:10 的最新修訂
$ifTversusJ is the command to estimate the temperature in the channel loss. The command is
$ifTversusJ type thermal_resistance_P1 Currently type is 1.
P1 is the thermal resistance Power loss would be the joul-heat-loss, nonradiative recombination loss, Auger recombination loss
$ifTversusJ 1 0.01
The $ifTversusJ setting for 1D-DDCC in GUI interface