$currentprecision is the command to set the current convergence criteria. Usually the DDCC program solve the program until the error is smaller than $error. The $error is from the potential error where ΔEc<$error. However, when the currentprecission is set, the program will also request the simulation program to get current density error in each iteration smaller than the $currentprecision.

(Ji+1Ji)Ji< $currentprecision

$currentprecision
1.0e-3

The $currentprecision setting for 1D-DDCC in GUI interface

1.Press the Additional Functions.
2.Press the Inpact Ionization.
3.Setting currentprecision.