Function for calculate the exciton distribution. Exciton will follow this equation


dnexdt=D2nex(r)nex(r)τγnex(r)2+G


Where 

  • D is diffusion coefficient.
  • τ is relaxation time of exciton.
  • γ is annihilation rate constant.
  • G is exciton generation rate.

Format

$callexciton
n
d kr knr gamma g

Parameter Explanation

  • n : the number of tables we usually set n as 5.
  • d : diffusion coefficient. (cm2)s1
  • kr : radiatvie rate constant (s1)
  • knr :non-radiative rate constant (s1)
  • gamma : quenching coefficient. (cm2)s1
  • g : generation rate if you wanna let whole recombination rate change into exciton you should set g as 1.

Example

$callexciton
5
2e-14 20000 3000 1e-12 1
2e-14 20000 3000 1e-12 1
2e-14 20000 3000 1e-12 1
2e-14 20000 3000 1e-12 1
2e-14 20000 3000 1e-12 1