$usefieldmufunc

出自DDCC TCAD TOOL Manual
於 2017年8月23日 (三) 14:17 由 Mikekung2留言 | 貢獻 所做的修訂
跳至導覽 跳至搜尋
可列印版不再被支援且可能有渲染錯誤。請更新您的瀏覽器書籤並改用瀏覽器預設的列印功能。

This function modifies the calculation method of mobility. Both electron and hole mobilities are considered electrical field-dependent terms with the default. However, you can define this function by using function usefielddependent_n(indEl, matind ,Ex,Ey,T,xp,yp) and function usefielddependent_p(indEl, matind, Ex, Ey, T, xp, yp).
The default follows the equation:

μ=μ0×exp(βF),

where

  • μ is the mobility,
  • μ0 is the zero-field mobility,
  • β is the factor of the field dependence, and
  • F is the localized electric field.


Format
$usemunpfunc
    1  μe  βe  μh  βh


Parameter explanation
  • μe: the zero-field mobility of electron. (cm2eV1s1)
  • βe: the factor of electron. (eV1/2)
  • μh: the zero-field mobility of hole. (cm2eV1s1)
  • βh: the factor of hole. (eV1/2)


Related commands
function usefielddependent_n(indEl, matind ,Ex,Ey,T,xp,yp), function usefielddependent_p(indEl, matind, Ex, Ey, T, xp, yp), $useemunfunc, $useemupfunc