$usemubydopeT
出自 DDCC TCAD TOOL Manual
$usemubydopeT is to enable the temperature and carrier density dependent mobility module with the predefined function. The function is designed for each region. So if total n regions is used, then you will need to setup n regions. The format is
$usemubydopeT Type_R1 p1 p2 p3 p4 p5.....p12 Type_R2 p1 p2 p3 p4 p5.....p12 Type_R3 p1 p2 p3 p4 p5.....p12 ... ... ... Type_RN p1 p2 p3 p4 .....p12
Type
0: Use the original mobility defined in parameter setions 1: , and 2: , and 3: , , and , .
If the mobility is for activated dopant density then
21: , and 31: , , and , .
The $usemubydopeT setting in GUI interface is here
After setting up the general structure, press Thermal, check the box and set the fields as needed!