$usetaunrbyfunc is to enable the temperature and carrier density dependent lifetime module with the predefined function. The function is designed for each region. So if total n regions is used, then you will need to setup n regions. The format is

$usetaunrbyfunc
Type_R1  p1 p2 p3 p4 .....
Type_R2  p1 p2 p3 p4 .....
Type_R3  p1 p2 p3 p4 .....
...
...
... 
Type_RN  p1 p2 p3 p4 .....