$fieldenhancemultitraps

出自DDCC TCAD TOOL Manual
跳至導覽 跳至搜尋

Setting for traps (2D) with multi-levels and field enhanced traps.

Format

$fieldenhancemultitraps
Nlevels
Ntrap Et degeneracy τe1 τp1 β Efactor   Ntrap2 Et degeneracy  τe,2  τp,2 β Efactor   ... (... Repeat  Nlevels) ... NtrapN Et degeneracy  τe,N  τp,N β Efactor 
Ntrap Et degeneracy τe1 τp1 β Efactor Ntrap2 Et degeneracy  τe,2  τp,2 β Efactor  ... (... Repeat  Nlevels) ... NtrapN Et degeneracy  τe,N  τp,N β Efactor 
...
...
...
Ntrap Et degeneracy τe1 τp1 β Efactor  Ntrap2 Et degeneracy  τe,2  τp,2 β Efactor  ... (... Repeat  Nlevels) ... NtrapN Et degeneracy  τe,N  τp,Nβ Efactor 

Parameter Explanation

  • Nlevels
  • Ntrap : trap density. cm3 negative sign as electron trap and poisitive sign as hole trap
  • Et : depth of trap related to Ec. (eV)
  • degeneracy : degeneracy of traps, we usually set as 1.
  • τe : nonradiative lifetime of electrons. (Sec.)
  • τh : nonradiative lifetime of holes. (Sec.)
  • β Efactor : enhanced factor with exp(β|E|Efactor)


Note that usually τ=1Ntvthσ. Therefore, when Nt is increased, the non-radiative lifetime should decrease as well. Users need to adjust this by themselves.


Example

$fieldenhancemultitraps
2
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 

This means 2 trap levels. One is electron trap where the trap level is below conduction band 1.1eV. The other trap levels is hole trap levels, which is below conduction band 2.1 eV.