$fieldenhancemultitraps
出自 DDCC TCAD TOOL Manual
Setting for traps (2D) with multi-levels and field enhanced traps.
Format
$fieldenhancemultitraps Et degeneracy Et degeneracy ... (... Repeat ) ... Et degeneracy Et degeneracy Et degeneracy ... (... Repeat ) ... Et degeneracy ... ... ... Et degeneracy Et degeneracy ... (... Repeat ) ... Et degeneracy
Parameter Explanation
- : trap density. negative sign as electron trap and poisitive sign as hole trap
- Et : depth of trap related to Ec.
- degeneracy : degeneracy of traps, we usually set as 1.
- : nonradiative lifetime of electrons.
- : nonradiative lifetime of holes.
- : enhanced factor with
Note that usually . Therefore, when Nt is increased, the non-radiative lifetime should decrease as well. Users need to adjust this by themselves.
Example
$fieldenhancemultitraps 2 -1e+17 1.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 1e+18 2.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 -1e+17 1.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 1e+18 2.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 -1e+17 1.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 1e+18 2.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 -1e+17 1.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 1e+18 2.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 -1e+17 1.1 1 1.0e-7 1.0e-7 1.0e-4 0.5 1e+18 2.1 1 1.0e-7 1.0e-7 1.0e-4 0.5
This means 2 trap levels. One is electron trap where the trap level is below conduction band 1.1eV. The other trap levels is hole trap levels, which is below conduction band 2.1 eV.