$fieldenhancemultitraps

出自 DDCC TCAD TOOL Manual
前往: 導覽搜尋

Setting for traps (2D) with multi-levels and field enhanced traps.

Format

$fieldenhancemultitraps
N_{levels}
N_{trap} Et degeneracy \tau_{e1} \tau_{p1} \beta Efactor   N_{trap_2} Et degeneracy  \tau_{e,2}  \tau_{p,2} \beta Efactor   ... (... Repeat  N_{levels}) ... N_{trap_N} Et degeneracy  \tau_{e,N}  \tau_{p,N} \beta Efactor 
N_{trap} Et degeneracy \tau_{e1} \tau_{p1} \beta Efactor N_{trap_2} Et degeneracy  \tau_{e,2}  \tau_{p,2} \beta Efactor  ... (... Repeat  N_{levels}) ... N_{trap_N} Et degeneracy  \tau_{e,N}  \tau_{p,N} \beta Efactor 
...
...
...
N_{trap} Et degeneracy \tau_{e1} \tau_{p1} \beta Efactor  N_{trap_2} Et degeneracy  \tau_{e,2}  \tau_{p,2} \beta Efactor  ... (... Repeat  N_{levels}) ... N_{trap_N} Et degeneracy  \tau_{e,N}  \tau_{p,N}\beta Efactor 

Parameter Explanation

  • N_{levels}
  • N_{trap} : trap density. cm^{-3} negative sign as electron trap and poisitive sign as hole trap
  • Et : depth of trap related to Ec. (eV)
  • degeneracy : degeneracy of traps, we usually set as 1.
  • \tau_{e} : nonradiative lifetime of electrons. (Sec.)
  • \tau_{h} : nonradiative lifetime of holes. (Sec.)
  • \beta Efactor : enhanced factor with exp(\beta |E
|^{Efactor})


Note that usually  \tau = \frac{1}{N_{t}v_{th}\sigma} . Therefore, when Nt is increased, the non-radiative lifetime should decrease as well. Users need to adjust this by themselves.


Example

$fieldenhancemultitraps
2
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 
-1e+17  1.1  1  1.0e-7  1.0e-7 1.0e-4 0.5  1e+18  2.1  1  1.0e-7  1.0e-7  1.0e-4 0.5 

This means 2 trap levels. One is electron trap where the trap level is below conduction band 1.1eV. The other trap levels is hole trap levels, which is below conduction band 2.1 eV.

$traps (2D) $fieldenhancetraps $multitraps