行 3: | 行 3: | ||
<math> G = a \times |E|^{p} \times exp\left( - \frac{b}{|E|} \right) +a2 \times |E|^{p2} \times exp\left( - \frac{b2}{|E|} \right) </math> |
<math> G = a \times |E|^{p} \times exp\left( - \frac{b}{|E|} \right) +a2 \times |E|^{p2} \times exp\left( - \frac{b2}{|E|} \right) </math> |
||
− | The unit of b is |
+ | The unit of b is V/cm |
The unit of a is <math>cm^{-3}s^{-1}</math> |
The unit of a is <math>cm^{-3}s^{-1}</math> |
||
行 18: | 行 18: | ||
In each layer, you will need to set the a b p coefficients. |
In each layer, you will need to set the a b p coefficients. |
||
− | If you don't want to consider BTBT in this layer. please set a and a2 0.0 |
+ | If you don't want to consider BTBT in this layer. please set a and a2 equal to 0.0. |
於 2021年3月7日 (日) 19:00 的最新修訂
Modeling the band to band tunneling (BTBT) with the BTBT formalism. The band to band tunneling rates are decided by
The unit of b is V/cm The unit of a is
For example:
$useBTBT a b p a2 b2 p2 a b p a2 b2 p2 a b p a2 b2 p2 a b p a2 b2 p2 ... ... ... N layers
In each layer, you will need to set the a b p coefficients. If you don't want to consider BTBT in this layer. please set a and a2 equal to 0.0.