For some output summary file, we would like to take summary of IQE in certain region, hence we will need to setup the output range of IQE, Auger, SRH, and Generation

$outputrangesetting
Type_of_Method N_num_tobesummed
R1
R2
R3
R4 ....
 Type_of_Method = 1:  only IQE calculated with selected regions
 Type_of_Method = 2:  IQE, Auger, SRH calculated with selected regions
 Type_of_Method = 3:  only Auger calculated with selected regions
 Type_of_Method = 4:  only SRH calculated with selected regions
 

For example, if we want to output region 4 5 6 7 9

$outputrangesetting
1 5
4
5
6
7
9



The $outputrangesetting setting in GUI interface is here
1. Press output range setting.
2. Check the box, select the type of method, and choose the regions as needed!