$heatbndistance
出自 DDCC TCAD TOOL Manual
$heatbndistance is the command to assign the heat absorbing boundary distance.
The format is
$heatbndistance distance(cm)
For example
$heatbndistance 500.0e-4
This means the thermal boundary condition ($contact is assigned 91) has a heat absorbing boundary at the distance of 500um.
The $heatbndistance setting in GUI interface is here
Check the box and fill in the field for abc distance (cm) as needed!
related commands:
$heatsource, $timeevolve, $usechannelaveT, $heatiterative, $thermaldiff
$maxTlimit, $useevversusT, $heatbndistance, $heatsolvebytime